We've compiled all common e-ink display FAQs into this comprehensive resource. If you have additional questions, please visit our FAQ tool.
VIEW FAQ TOOL1. External Check: Check whether the e-ink display FPC is inserted reversely, whether the FPC socket is damaged, whether there is faulty soldering, and whether the FPC is torn. If using our development board, check whether the P3 short-circuit cap is connected and whether the RESE dial switch is selected correctly.
2. Hardware Check: Measure the voltage of PREVGH and PREVGL to see if the boost is successful. Check relevant peripheral circuits, especially the MOS tube.
3. Software Check: If boost is normal, check the software part, driver and pin definition. Test the SCL and SDA signals and confirm correctness by comparing the SPI waveform in the specification.
It needs to be shielded from direct sunlight, with moisture-proof and waterproof measures. Operate within the temperature and humidity range specified. When not used for long periods, place upside down with screen showing all white.
The refresh interval of SPI serial tri-color E-ink should be at least 180s, especially for large sizes. Too short intervals may cause ghosting.
Number of pixels in 1 inch. Example: 1.54 inch resolution 152x152, AA area 27.5x27.5, DPI=152/(27.5/25.39)=140
Input voltage is generally 2.3-3.6V (3.3V recommended). Add boost test points for maintenance. Use 10uH 1A winding inductance, Si1304BDL or Si1308EDL for MOS, schottky diode like MBR0530, and capacitors with 25V+ withstand voltage.
Our STM32, ESP32, ESP8266 and Arduino platforms have USB-to-serial chips for direct PC connection via USB for serial operation and download.
For Windows, use Image2Lcd (registration code "0000-0000-0000-0000-6A3b") or our ImageToEPD software. See specifications for usage.
Problem 1: Can't compile - Ensure Keil is correctly installed with J-link driver.
Problem 2: Keil4 project in Keil5 - Recompile the project with Keil5 first.
Problem 3: Flash download failed - Add Flash option in Keil5.
Problem 4: Original image displayed - Confirm recompilation after image update.
If you didn't find the answer to your question, please contact our technical support team.